Breaking: Explosion at Hoover Dam
2022-07-19
[Publish Twitter] 24 hr rule
Posted by:Frank G

#18  Besoaker

Current temps in the 60F in London - will probably not top 80F tomorrow. But still a lot of summer is left.
Posted by: Lord Garth   2022-07-19 22:52  

#17  Sadly I expect the cost and time to repair will exceed the original cost and time to build the entire Hoover Dam.

And a few 80 year old+ machinists may need pulled out of retire homes to hand make a few of the parts.
Posted by: Airandee   2022-07-19 19:35  

#16  AP - UK breaks record for highest temperature as Europe sizzles
Posted by: Besoeker   2022-07-19 18:14  

#15  The 100+ degree temperatures in the southwest don't play nicely with the wind or solar generation either.

Generators/Bushings/Bearings in the Wind Turbines and Solar Panel chemistry and structures.

I expect more system and/or grid failures soon.
Posted by: Mullah Richard   2022-07-19 18:00  

#14  The whole southwest grid is overstressed. With Lake Mead low, the station generators and systems have to work harder as there's a lower water flow through the turbines. That heats everything up.
Posted by: Mullah Richard   2022-07-19 17:35  

#13  This one's not nearly as big as the kind Mullah Richard is describing, but it's still impressive...

Posted by: M. Murcek   2022-07-19 17:02  

#12  ^^^^ 'Needles' = 'Needless'
Posted by: Mullah Richard   2022-07-19 16:56  

#11  ^^^ Needles to say that these transformers are the size of a small house. The photos don't do them justice for their actual size.
Posted by: Mullah Richard   2022-07-19 16:55  

#10  ^^You are correct. When I was there in the early 1990's on a 'deep tour' with an Electrical Group, these were still the old Westinghouse transformers from the 1930's that had been upgraded with cooling fans and to use the newer non-carcinogenic insulating oil.

Each of the 17 turbine generators produces roughly 16,500 Volts per phase. The 2,500 KVA larger single-phase transformers (there are 2 smaller ones for plant operations) step that up to 500,000 volts for transmission.
Posted by: Mullah Richard   2022-07-19 16:53  

#9  ^ These would be the sort of large transformers I have read are not quickly replaceable off the shelf.
Posted by: M. Murcek   2022-07-19 15:22  

#8  The outside area there contains oil-filled stepup transformers. They can explode and produce a LOT of smoke until the oil burns off.
Posted by: Mullah Richard   2022-07-19 15:19  

#7  Explosion at Hoover Dam: Huge fireball rises up from turbine house as black smoke engulfs the Nevada landmark
Posted by: Skidmark   2022-07-19 14:39  

#6  Hoover Dam Design, Construction and Facts

Hoover Dam
Frequently Asked Questions and Answers


Not something you want to fail during the hottest week of the summer.
Posted by: Skidmark   2022-07-19 14:34  

#5  Hoover Dam
Posted by: Skidmark   2022-07-19 14:27  

#4  Photos with schematic
Posted by: Skidmark   2022-07-19 14:24  

#3  Turbine room area?
Posted by: Black Charlie Slairt1430   2022-07-19 14:11  

#2  Transformer exploding? A later vid shows just a little fire right there after the explosion one.
Posted by: DarthVader   2022-07-19 14:10  

#1  Aged overworked energy infrastructure collapsing under Biden?
Posted by: Black Charlie Slairt1430   2022-07-19 14:04  